Permit: T08PL00125

Parcel: 124032660


Addresses:

1810 E 7TH ST


Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Permit Number - T08PL00125

Inspection Description - PLUMBING - GAS PRESSURE TEST

Inspection Status - Approved

Date Description Inspector Results Comments
01/30/2008 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection :*
1. SECURE THE WATER HEATER ENCLOSURE
2. REQUIRE "B" VENT ABOVE ENCLOSURE - TO EXTEND AT LEAST TWO FEET ABOVE ROOF
3. REQUIRE SEDIMENT TRAPS AT FURNACE AND WATER HEATER
4. INSTALL ALL VALVES AND FLEXES - DO NOT TEST THRU APPLIANCES

RETEST SYSTEM
01/28/2008 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection :
See detailed listing on site.| 999*
- POST ADDRESS
- PROVIDE 1" CLEARANCE BETWEEN B-VENT AND SVCE
- SECURE TO SVCE W/B-VENT CLAMP NOT TAPE
- CONNECT BONDING TO NEW PIPE (GROUND WIRE)
- SECURE 1/2 PIPE NEAR WH
- PROVIDE A LADDER TO ACCESS ROOF
- PROVIDE PROOF OF INSPECTION FOR NEW ROOFTOP UNITS
- SECURE PIPING IN WALL BEHIND STOVE
01/23/2008 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection :*
POST YOUR ADDRESS
INSPECTORS DO NOT ENTER OCCUPIED RESIDENCES
WITHOUT AN ESCORT.