Inspection History Details
Inspection Status: Approved
Inspection History: SITE - SEWER
Permit Number - T08PL00046
Inspection Description - SITE - SEWER
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/26/2010 | SITE - SEWER | Approved | IVRS - Inspection :* | |
| 08/05/2010 | SITE - SEWER | Partial Approval | IVRS - Inspection :* | |
| 02/11/2010 | SITE - SEWER | Not ready for Inspection | IVRS - Inspection :* 1. NEED AUTHORIZATION TO DISCHARGE FROM PC DEQ 2. WOOD TERMINATION OR TRACER WIRES IN MANHOLES WITH CORRECT TERMINATION OF MANHOLE COVERS TO PIMA COUNTY & CITY OF TUCSON STANDARDS |
|
| 10/23/2008 | SITE - SEWER | Partial Approval | IVRS - Inspection :* RETEST MANHOLE #3 OK #7 OK #8 OK #10 OK |
|
| 10/13/2008 | SITE - SEWER | Partial Approval | IVRS - Inspection :* VACUUM TESTING MANHOLES #2 - OK #3 - FAILED #4 - OK #5 - OK #6 - OK #7 - FAILED #8 - FAILED #9 - OK #10 - FAILED #11 - OK |
|
| 10/07/2008 | SITE - SEWER | Not ready for Inspection | IVRS - Inspection :* VACUUM COMPRESSOR BROKEN, NO THIRD PARTY INSPECTOR ON SITE |
|
| 09/23/2008 | SITE - SEWER | Partial Approval | IVRS - Inspection :* AIR TEST 6" BCS's FROM MANHOLE #3 TO C.O. #1 & #2 OK FROM MANHOLE #4 TO C.O. #3 OK MANHOLE #5 TO C.O. #4, #5, #6 OK MANHOLE #5 TO C.O. #7 & C.O #8 OK MANHOLE #8 TO C.O. #9 OK MANHOLE #9 TO C.O. #10, #11, #12 OK MANHOLE #10 TO C.O. #13 OK 4" BCS MANHOLE #11 TO C.O. #14 OK |
|
| 09/19/2008 | SITE - SEWER | Not ready for Inspection | IVRS - Inspection :* CONTRACTOR CANCELED |
|
| 09/18/2008 | SITE - SEWER | Partial Approval | IVRS - Inspection :* AIR TESTING - 8" SEWER FROM EXISTING PIMA COUNTY MANHOLE TO MANHOLE #1 OK MANHOLE #1 TO #2 OK MANHOLE #2 TO #3 OK MANHOLE #3 TO #4 OK MANHOLE #4 TO #5 OK MANHOLE #5 TO #6 OK MANHOLE #6 TO #7 OK MANHOLE #7 TO #8 OK MANHOLE #8 TO #9 OK MANHOLE #8 TO #10 OK MANHOLE #10 TO #11 OK NEED TEST ON HCS LATERALS, VACUUM TESTING ON MANHOLES AND PCDEQ AUTHORIZATION TO DISCHARGE PRIOR TO HCS CONNECTION TO BLD. |
|
| 09/17/2008 | SITE - SEWER | Partial Approval | IVRS - Inspection :* 1. 8" SDR FROM MANHOLE #10 TO #11 2. 6" FROM MANHOLE #10 TO BLD #10 3. 4" DUCTILE TRANSITION TO SDR35 FROM MANHOLE #11 TO BLD. #19 4. MANHOLE #10 & MANHOLE #11 BASES POURED 5. BEDDING TRACER, SHADING 6. 6" SDR35 FROM MANHOLE #8 TO BLD. #6 7. 6" FROM MANHOLE #5 TO BLD. #3 AND BLD. #4 |
|
| 09/16/2008 | SITE - SEWER | Not ready for Inspection | IVRS - Inspection :* CONTRACTOR CANCELED |
|
| 09/12/2008 | SITE - SEWER | Partial Approval | IVRS - Inspection :* 1. SDR 35 FROM MANHOLE #8 TO #10 BEDDING & TRACER WIRE OK TO BE TESTED AT LATER DATE 2. MANHOLES #1 & #2 POUR BACK TRACER WIRE AT TOP |
|
| 09/11/2008 | SITE - SEWER | Not ready for Inspection | IVRS - Inspection :* GATE LOCKED NO ONE ON SITE |
|
| 09/10/2008 | SITE - SEWER | Not ready for Inspection | IVRS - Inspection :* | |
| 09/09/2008 | SITE - SEWER | Partial Approval | IVRS - Inspection :* 1. 3-STUB FROM MANHOLE #9 SDR35 TRACER WIRE AND BEDDING OK NO TEST AIR TEST TO BE DONE AT LATER DATE |
|
| 09/05/2008 | SITE - SEWER | Partial Approval | IVRS - Inspection :* MANHOLE BASE #9 CORRECTED 6" SDR 35 FROM MANHOLE #3 TO BLD. #1 MANHOLE #4 TO BLD. #2 MANHOLE #5 TO BLD. #5 |
|
| 09/04/2008 | SITE - SEWER | Partial Approval | IVRS - Inspection :* MANHOLE BASES THRU #9 POURED & STACKED WITH HCS's AS REQUIRED. MANHOLE BASE #9 - 8" OUTLET IS REQUIRED TO NOT HAVE BELL END (FLEXIBLE CONNECTION) DIRECTLY EMBEDDED IN CONCRETE BASE. 8" SDR PIPING FROM PIMA COUNTY EXISTING THRU MANHOLE #9 INCLUDING 8" STUB TOWARD MANHOLE #10 BEDDING, LAYING, TRACER, SHADING PER REVISION (2) RWS 8/11/08 |
|
| 08/29/2008 | SITE - SEWER | Partial Approval | IVRS - Inspection :* 8" SDR 35 CONTINUES TO MANHOLE #7 TO #8 AND STUBBED OUT OF #8 BEDDING, LAYING, TRACER, SHADING MANHOLE BASES PER #6 AND #7 POURED #8 POURED WITH 8" STUB NORTH, 8" STUB EAST 6" STUB WEST |
|
| 08/28/2008 | SITE - SEWER | Partial Approval | IVRS - Inspection :* 8" SDR CONTINUES TO MANHOLE #6 GOES EAST APP. 100' BEDDING, LAYING, TRACER, SHADING |
|
| 08/26/2008 | SITE - SEWER | Partial Approval | IVRS - Inspection :* 8" SDR CONTINUES TO 15' FROM MANHOLE #6 |
|
| 08/25/2008 | SITE - SEWER | Partial Approval | IVRS - Inspection :* MANHOLE #3 & #4 STACKED 8" SDR 35 CONTINUES TO MANHOLE #5 CONTINUOUS NORTH APP. 100' SOUTH OF MANHOLE #6 BEDDING, LAYING, TRACER, SHADING |
|
| 08/22/2008 | SITE - SEWER | Partial Approval | IVRS - Inspection :* MANHOLE #1 & #2 STACKED MANHOLE #3 & #4 ARE POURED WITH 6" HCS STUBS INSTALLED, 8" SDR 35 CONTINUOUS NORTH FROM MANHOLE #4 APP. 120' TOWARD MANHOLE #5 ENGINEER TO PROVIDE A PLAN THAT IS READABLE WITH DETAILS THAT ARE READABLE AND A SIZING CHART FOR ALL BUILDING HCS LATERALS. |
|
| 08/21/2008 | SITE - SEWER | Partial Approval | IVRS - Inspection :* CONTINUATION OF 8" SDR35 TO MANHOLE #3, CONTINUES WEST TO MANHOLE #4, CONTINUES AIP 80' NORTH TOWARD MANHOLE #5 -- BEDDING, LAYING, TRACER OK |
|
| 08/19/2008 | SITE - SEWER | Partial Approval | IVRS - Inspection :* 8" SDR CONTINUES TO MANHOLE #2, FROM #2 TO #3 TRANSITION TO DUCTILE IRON BACK TO SDR 35 CONTINUES TO APP. 40' FROM MANHOLE #3 BEDDING, LAYING, TRACER WIRE SHADING. BASE OF MANHOLE #1 & #2 POURED |
|
| 08/13/2008 | SITE - SEWER | Partial Approval | 8" SDR 35 FROM EXISTING PIMA COUNTY MANHOLE TO REVISED NEW MANHOLE #1 - BEDDING, LAYING, TRACER OK TO SHADE AND START BACKFILL WITH 3RD PARTY INSPECTOR OK 8" SDR 14' OUT OF MANHOLE #1 HEADING NORTH |