Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: CERTIFICATE OF OCCUPANCY
Permit Number - T08OT02814
Inspection Description - CERTIFICATE OF OCCUPANCY
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/13/2009 | CERTIFICATE OF OCCUPANCY | Approved | IVRS - Inspection :* | |
01/12/2009 | CERTIFICATE OF OCCUPANCY | Not ready for Inspection | IVRS - Inspection :* NEED FIRE FINAL -- ALL CORRECTIONS BELOW HAVE BEEN COMPLETED *PLEASE CORRECT ABOVE ADDRESS SHOULD READ 1310 S. ALVERNON |
|
12/02/2008 | CERTIFICATE OF OCCUPANCY | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. PROVIDE APPROVED SITE & FLOOR PLANS 2. REMOVE DEADBOLT ON REAR DOOR. USE PANIC HARDWARE ONLY. REMOVE THROW BOLT ON BAR EXIT. DO NOT BLOCK 2ND BAR EXIT 3. REMOVE SCREEN DOORS @ EXITS MUST SWING IN DIRECTION OF TRAVEL 4. ILLUMINATED EXIT SIGN WITH BATTERY BACK-UP REQUIRED AT FRONT & REAR EXITS 5. EMERGENCY EGRESS LIGHTING WITH BATTERY BACK-UP REQUIRED IN ALL ROOMS 6. "DOOR TO REMAIN UNLOCKED..." SIGN REQUIRED AT FRONT DOOR 7. DO NOT BLOCK 2ND EXIT FROM FRONT BAR AREA 8. POST OCCUPANT LOAD SIGNS IN EACH ASSEMBLY AREA 9. REVERSE PRESSURE ASSEMBLY REQUIRED AT CARBONATORS 10. ATMOSPHERIC VACUUM BREAKERS REQUIRED ON ALL HOSE BIBS 11. ALL INDIRECT WASTE TO BE PROPERLY PITCHED AND TERMINATED 1" ABOVE FLOOR SINKS 12. INSTALL GFCI PLUG RECEPTACLE BETWEEN SINK AND SPEED RACK @ BAR |