Permit: T08OT02007

Parcel: 121080610


Addresses:

6226 E LEE ST


Inspection Status: Approved

Inspection History: CERTIFICATE OF OCCUPANCY

Permit Number - T08OT02007

Inspection Description - CERTIFICATE OF OCCUPANCY

Inspection Status - Approved

Date Description Inspector Results Comments
01/05/2009 CERTIFICATE OF OCCUPANCY Approved IVRS - Inspection :*
I NEED TFD TO APPROVE FOR TCO
08/29/2008 CERTIFICATE OF OCCUPANCY Not ready for Inspection IVRS - Inspection :*
1. COVER OR REMOVE PLUG RECEPTACLES @ EAST
2. ALL EXTERIOR HOSE BIBS MUST HAVE ANTI-SIPHON DEVICES
3. SMOKE DETECTORS (INTERCONNECTED) REQUIRED
4. CAULK TOILETS @ FLOOR AND ALL LAVATORIES @ WALL
5. BLANK ALL OPENINGS IN SUB-PANELS
6. MAKE SURE PANELS ARE LABELED CORRECTLY
7. EXTERIOR OUTLET @ SOUTH END OF NORTH WING TO BE GFCI AND HAVE BUBBLE COVER
8. CLEAN OUT BEHIND DRYER
9. SUB-PANEL @ N.END OF E.WING HAS 2 CIRCUITS THAT SHOULD HAVE MAX. 15A DISCONNECT
10. HAVE CORRECT COVERS ON EXTERIOR PLUG RECEPTACLES
11. ALL ELECTRIC OUTLETS & JUNCTION BOXES AROUND EXTERIOR OF BUILDINGS SHOULD BE PROPERLY CLOSED
12. SHOULD THIS BE CLASSIFIED AS R-1 THEN WE WILL NEED TO ADDRESS ACCESSBILITY