Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - RECONNECT
Permit Number - T08MH00055
Inspection Description - ELECTRIC - RECONNECT
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/22/2008 | ELECTRIC - RECONNECT | Approved | IVRS - Inspection :* | |
08/19/2008 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) POST UNIT NUMBER 2) SECURE STEPS TO UNIT 3) STEPS OVER 30" IN HEIGHT REQUIRE HANDRAILS 4) COVER PLATES MISSING THROUGHOUT 5) INSTALL SMOKE DETECTORS IN BEDROOMS 6) PROVIDE COMBUSTION RELIEF TO EXTERIOR WATER HEATER IN MASTER BEDROOM CLOSET 7) MISSING LIGHT FIXTURE LIVING ROOM CEILING EXPOSED WIRING |