Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - RECONNECT
Permit Number - T08MH00028
Inspection Description - ELECTRIC - RECONNECT
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/04/2008 | ELECTRIC - RECONNECT | Approved | IVRS - Inspection :* | |
07/21/2008 | ELECTRIC - RECONNECT | Not ready for Inspection | IVRS - Inspection :* 1) 100 SERV=#4 #8 GRD 2) TWO POLE FOR 30/30 CIRCUIT, BREAKERS NOT TIED TOGETHER 3) NEED M/H TO BE SET UP AND INSPECTED 4) NEED MAIN BREAKER AT PEDESTAL 5) NEED POWER SOURCE FOR RANGE/OVEN 6) NEED PROPANE FOR FURNACE 7) PUT ROMEX IN CONDUIT AT FURNACE 8) 100 AMP SERV. WON'T SUPPORT AN ELECTRIC RANGE CIRCUIT |