Inspection History: MECHANICAL - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/19/2008 | MECHANICAL - INTERMEDIATE | Not Applicable | ||
| 12/12/2008 | MECHANICAL - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NO ONE PRESENT AT 10:30 AM-RANG BELL 2) PLEASE RE-CALL |
|
| 11/25/2008 | MECHANICAL - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1) NO ACCESS 11:07 AM 2) RECALL INSPECTION |
|
| 11/19/2008 | MECHANICAL - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) DRIP LEG REQUIRED ON WATER HEATER GAS 2) T/P LINE MUST BE HARD PIPED AND REAR DOWN HILL. A PAN CAN BE USED 3) LEAK AT WATER HEATER HOT WATER FLEX 4) CONDENSATE DRAIN CANNOT ENTER PLUMBING VENT-RUN OFF ROOF ELECTRIC: 5) GET PERMIT FOR PANEL AND CALL FOR INSPECTION 6) BOND GAS LINE 7) G-2411.1 GROUND WIRE GOES UNDER ACORN CLAMP OPPOSITE BOLT |