Permit: T08ME00645

Parcel: 136031000


Addresses:

1852 S CAMINO SECO

Inspection Status: Approved

Inspection History: MECHANICAL - FINAL

Date Description Inspector Results Comments
03/17/2010 MECHANICAL - FINAL Approved IVRS - Inspection :*
1) CORRECTIONS HAVE BEEN MADE
11/13/2008 MECHANICAL - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SEAL CEILING OF EXISTING FURNACE ROOM
2) PAINT CONDENSATE DRAIN
3) PROVIDE LOAD CALCS FOR ADDED LOAD OF A/C UNIT IN MAIN PANEL TO BE SOME COLOR OTHER THAN WHITE FOR POWER AND GREEN FOR GROUND OR BARE
5) USE GROMMET OR OTHER APPROVED DEVICE TO PROTECT WIRE FROM DISCONNECT INTO UNIT
6) WHAT SIZE WIRE USED ? #6 REQUIRED FOR 60 AMPS
7) STRUCTUAL (BLDG) PERMIT REQUIRED FOR ROOF LOAD OF A/C UNIT