Permit: T08ME00441

Parcel: 133030810

Inspection Status: Approved

Inspection History: MECHANICAL - FINAL

Date Description Inspector Results Comments
08/21/2008 MECHANICAL - FINAL Approved IVRS - Inspection :*
08/15/2008 MECHANICAL - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) INSTALL DRIP LEG ON GAS LINE
2) INSTALL SAFETY CUT OFF SWITCH OR SECONDARY CONDENSATE DRAIN
3) SECURE GAS PIPE TO WALL (HINGED PIPE)
4) MAX FUSE SIZE 50 AMPS
5) USE COPPER FOR CONDENSATE DRAIN WHERE EXPOSED TO SUNLIGHT AND RUN TO EDGE OF ROOF SUPPORTED EVERY 6'
07/28/2008 MECHANICAL - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NO ACCESS TO HOUSE
2) NO ELECTRIC RUN TO UNIT ON ROOF
3) FURNACE VENT LAYING ON ROOF
4) COMPLETE WORK BEFORE CALLING FOR INSPECTIONS