Permit: T08ME00264

Parcel: 12209215C


Addresses:

4009 E JUSTIN LN

Inspection Status: Partial Approval

Inspection History: MECHANICAL - FINAL

Date Description Inspector Results Comments
07/17/2008 MECHANICAL - FINAL Partial Approval IVRS - Inspection :*
1) ALL ITEMS CALLED OUT OK AT THIS TIME
2) NEED TO INSULATE DUCT TO A MIN R.8/SEAL ALL JOINTS
07/02/2008 MECHANICAL - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NEED ACCESS INTO HOUSE TO CHECK JUNCTION BOX IN ATTIC
2) NO ONE HOME, NO NUMBER LEFT TO CALL
06/13/2008 MECHANICAL - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NEED TO RE-IDENTIFY NUETRAL BEING USED AS AN UNGROUNDED CONDUCTOR
2) WRONG FUSE IN DISCONNECT BOX FOR A/C, S/B 20 AMP MAX PER LISTING ON UNIT
3) NEED TO LEVEL A/C UNIT
4) NEED TO SUPPORT JUNCTION BOX IN ATTIC AND SECURE CONDUITS
5) NEED TO WATER PROOF STUCCO BACK WHERE CONDUITS PENETRATE
05/23/2008 MECHANICAL - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NO ONE HOME
2) PLEASE RECALL FOR INSPECTION