Permit: T08ME00169

Parcel: 136332040


Addresses:

2341 S THOMAS DR

Inspection Status: Approved

Inspection History: MECHANICAL - FINAL

Date Description Inspector Results Comments
10/01/2008 MECHANICAL - FINAL Approved IVRS - Inspection :*
09/29/2008 MECHANICAL - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
PLEASE SCHEDULE AN INSPECTION
WHEN SOMEONE WILL BE HOME
04/02/2008 MECHANICAL - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
- INSULATE SHEETMETAL DUCT IN FURNACE CLOSET
- ID CIRCUIT BREAKER
- CONDENSATE CANNOT TERMINATE ONTO THE PATIO
- DO NOT USE WHITE WIRE TO POWER A/C UNIT
- TAPE BOTH ENDS OF WHITE WIRE WITH BLACK TAPE
- PROVIDE THE REQUIRED GFI SERVICE RECEPTACLE ON ROOF WITH BUBBLE TYPE COVER
- PROVIDE THE REQUIRED DRAWING FOR NEW UNIT ON A ROOFTOP
- 1/2" GAS PIPE NOT ADEQUATE FOR 92,000 BTU
MORE THAN 30' AWAY FROM METER