Inspection History Details
Inspection Status: Approved
Inspection History: MECHANICAL - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/01/2008 | MECHANICAL - FINAL | Approved | IVRS - Inspection :* | |
| 09/29/2008 | MECHANICAL - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* PLEASE SCHEDULE AN INSPECTION WHEN SOMEONE WILL BE HOME |
|
| 04/02/2008 | MECHANICAL - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* - INSULATE SHEETMETAL DUCT IN FURNACE CLOSET - ID CIRCUIT BREAKER - CONDENSATE CANNOT TERMINATE ONTO THE PATIO - DO NOT USE WHITE WIRE TO POWER A/C UNIT - TAPE BOTH ENDS OF WHITE WIRE WITH BLACK TAPE - PROVIDE THE REQUIRED GFI SERVICE RECEPTACLE ON ROOF WITH BUBBLE TYPE COVER - PROVIDE THE REQUIRED DRAWING FOR NEW UNIT ON A ROOFTOP - 1/2" GAS PIPE NOT ADEQUATE FOR 92,000 BTU MORE THAN 30' AWAY FROM METER |