Permit: T08ME00086

Parcel: 125073700


Addresses:

2327 E 7TH ST

Inspection Status: Approved

Inspection History: MECHANICAL - FINAL

Date Description Inspector Results Comments
02/29/2008 MECHANICAL - FINAL Approved IVRS - Inspection :*
CORRECTIONS HAVE BEEN MADE
02/26/2008 MECHANICAL - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
- SECONDARY DRAIN CANNOT BE TIED INTO SAME PIPING AS PRIMARY DRAIN.
- ALL PVC PIPING MUST HAVE PRIMER ON JOINTS.
02/21/2008 MECHANICAL - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
- PROVIDE AN OVERFLOW SENSOR ON SECONDARY DRAIN OUTLET ON COIL.
- PVC DRAIN IS TOO CLOSE TO FURNACE VENT CONNECTOR
- USE COPPER TO GET PLASTIC 6" FROM VENT
- PROVIDE A HIGH COMBUSTION AIR VENT
- OK TO USE THE ONE OPENING METHOD
- RECALL FOR INSPECTION