Permit: T08ME00062

Parcel: 112040010


Addresses:

2725 E GLENN ST

Inspection Status: Approved

Inspection History: MECHANICAL - FINAL

Date Description Inspector Results Comments
03/06/2008 MECHANICAL - FINAL Approved IVRS - Inspection :*
02/27/2008 MECHANICAL - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
WATER HEATER FLUE PIPE NOT PER CODE
SINGLE WALL PIPING CANNOT PENETRATE CEILING OR RUN IN ATTIC SPACE
02/06/2008 MECHANICAL - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
PROVIDE P-TRAP AT COIL
PROVIDE SECONDARY DRAIN AT COIL
PROVIDE SEDIMENT TRAP AT GAS PIPING
PROVIDE GAS CONNECTION
PROVIDE SUPPOT FOR FLUE PIPING
COMBUSTION AIR TO BE WITHIN 12" OF FLOOR
02/05/2008 MECHANICAL - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
NO ACCESS TO HOME