12/03/2008 | VIOL - MEANS OF EGRESS | Violation | 1006.3 - Illumination emergency power. The power supply for means of egress illumination shall normally be provided by the premise's electrical supply. In the event of power supply failure, an emergency electrical system shall automatically illuminate… The emergency power system shall provide power for a duration of not less than 90 minutes and shall consist of storage batteries, unit equipment or an on-site generator. _____ Repair or replace batteries in emergency lighting |
|
12/03/2008 | VIOL - MEANS OF EGRESS | Violation | 1023.6 Access to a public way. The exit discharge shall provide a direct and unobstructed access to a public way. ___ Relocate rear exit to original location. |
|
12/03/2008 | VIOL - MEANS OF EGRESS | Violation | 1008.1.8.1 Hardware. Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. | |
12/03/2008 | VIOL - MEANS OF EGRESS | Violation | 3003.5 Security. Compressed gas containers, cylinders, tanks and systems shall be secured against accidental dislodgement and against access by unauthorized personnel in accordance with Sections 3003.5.1 through 3003.5.3. |