Case: T08FR04438

Parcel: 134071880


Addresses:

8509 E KENYON DR

Inspection Status: Approved

Inspection History: VIOL - MEANS OF EGRESS

Date Description Inspector Results Comments
12/19/2008 VIOL - MEANS OF EGRESS Approved
12/01/2008 VIOL - MEANS OF EGRESS Violation 1027.5 Illumination emergency power.

____Repair emergency lighting units located near the front and rear exit.
11/25/2008 VIOL - MEANS OF EGRESS Violation 1008.1.8.5 Unlatching. The unlatching of any door or
leaf shall not require more than one operation.
1008.1.8 Door operations. Except as specifically permitted
by this section egress doors shall be readily openable from
the egress side without the use of a key or special knowledge
or effort.

____Remove the second door knob from the northwest bedroom. Two door knobs on a door is considered special knowledge and requires more than one operation to open.
11/25/2008 VIOL - MEANS OF EGRESS Violation 1024.6 Access to a public way. The exit discharge shall provide
a direct and unobstructed access to a public way.

1007.2 Continuity and components. Each required accessible
means of egress shall be continuous to a public way
1026.1 General. In addition to the means of egress required by
this chapter, provisions shall be made for emergency escape
and rescue in Group R and I-1 occupancies. Basements and
sleeping rooms below the fourth story above grade plane shall
have at least one exterior emergency escape and rescue opening
in accordance with this section. Where basements contain one
or more sleeping rooms, emergency egress and rescue openings
shall be required in each sleeping room, but shall not be
required in adjoining areas of the basement. Such openings
shall open directly into a public way or to a yard or court that
opens to a public way.

1014.2 Egress through intervening spaces. Egress through
intervening spaces shall comply with this section.
Means of egress from dwelling units or sleeping
areas shall not lead through other sleeping
areas, toilet rooms or bathrooms.

____Currently the northwest bedroom does not have one acceptable exit that leads to a public way. One door leads through a bathroom. The second door leads to a small outside area approx 9'x5' which is blocked with a gate on one side and a block wall on the other. The third door leads through another sleeping area. The window leads to the swimming pool area which is fenced and locked. Provide approved plans if this bedroom was approved this way. If you cannot provide documentation, this will be reffered to Department of Neighborhood Resources.