Inspection Status: Violation
Inspection History: VIOL - BUILDING SVCS & SYSTEMS
Case Number - T08FR04366
Inspection Description - VIOL - BUILDING SVCS & SYSTEMS
Inspection Status - Violation
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/06/2009 | VIOL - BUILDING SVCS & SYSTEMS | Violation | TFC 605.4 - Multiplug adapters. Multiplug adapters, such as cube adapters, unfused plug strips or any other device not complying with the ICC Electrical Code shall be prohibited. Remove unapproved cube adaptors _____ above window E. of front door |
|
| 04/06/2009 | VIOL - BUILDING SVCS & SYSTEMS | Violation | TFC 605.4.2 - Power supply. Relocatable power taps shall be directly connected to a permanently installed receptacle. TFC 605.5 - Extension cords. Extension cords and flexible cords shall not be a substitute for permanent wiring. _____ Replace unapproved extension cord with approved relocatable power tap - sales counter. |
|
| 04/06/2009 | VIOL - BUILDING SVCS & SYSTEMS | Violation | TFC 605.6 - Unapproved conditions. Open junction boxes and open-wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. _____ Switchplates in Home Theater showroom _____ Junction Box in Office _____ Flourscent Light in Office _____ Outlet below counter behind sales desk. |
|
| 04/06/2009 | VIOL - BUILDING SVCS & SYSTEMS | Violation | TFC 605.5.3 - Maintenance. Extension cords shall be maintained in good condition without splices, deterioration or damage. _____ Remove damaged extension cords (temp bay). |
|
| 04/06/2009 | VIOL - BUILDING SVCS & SYSTEMS | Violation | TFC 605.4.3 - Installation. Relocatable power tap cords shall not extend through walls, ceilings, floors, under doors or floor coverings, or be subject to environmental or physical damage. _____ Provide approved impact protection for power cord at sales desk. _____ Remove cord extending through ceiling tiles above window East of front door. |
|
| 04/06/2009 | VIOL - BUILDING SVCS & SYSTEMS | Violation | TFC 605.4.1 - Power tap design. Relocatable power taps shall be of the polarized or grounded type, equipped with overcurrent protection, and shall be listed in accordance with UL 1363. _____ Remove unapproved relocatable power tap in office. |