Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: VIOL - MEANS OF EGRESS
Case Number - T08FR04319
Inspection Description - VIOL - MEANS OF EGRESS
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/18/2008 | VIOL - MEANS OF EGRESS | Approved | corrections have been made. | |
11/14/2008 | VIOL - MEANS OF EGRESS | Violation | 504.2 Maintenance of exterior doors and openings. Exterior doors and their function shall not be eliminated without prior approval. Exterior doors that have been rendered nonfunctional and that retain a functional door exterior appearance shall have a sign affixed to the exterior side of the door with the words THIS DOOR BLOCKED. The sign shall consist of letters having a principal stroke of not less than 0.75 inch (19.1 mm) wide and at least 6 inches (152 mm) high on a contrasting background. 1) You will remove the handle from the wielded door at the rear of the business. 2) You will place a sign on the exterior and interior of non functional door. |
|
11/14/2008 | VIOL - MEANS OF EGRESS | Violation | IFC 1011.1 Where required. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. 1) Place an illuminated exit sign above the door that leads to the exit access ( hallway leading to your exit). |