Case: T08FR04251

Parcel: 11519007F


Addresses:

1855 W GRANT RD

Inspection Status: Correction Required

Inspection History: VIOL - MEANS OF EGRESS

Date Description Inspector Results Comments
11/07/2008 VIOL - MEANS OF EGRESS Correction Required TFC 1028.3 Obstructions. A means of egress shall be free from
obstructions that would prevent its use.

_____1. Remove all storage obstructing the south exit door located in the shop.
11/07/2008 VIOL - MEANS OF EGRESS Correction Required TFC 1008.1.8 Door operations. Except as specifically permitted
by this section egress doors shall be readily openable from
the egress side without the use of a key or special knowledge
or effort.

_____1. Remove the double-keyed deadbolt from the caged area in the office.
NOTE:Replace the double-keyed deadbolt with a thumb-turn deadbolt. The thumb-turn side shall be located inside the cage.