Case: T08FR03579

Parcel: 12401002B


Addresses:

1339 E 1ST ST

Inspection Status: Approved

Inspection History: VIOL - MEANS OF EGRESS

Date Description Inspector Results Comments
12/11/2008 VIOL - MEANS OF EGRESS Approved
10/07/2008 VIOL - MEANS OF EGRESS Violation 1008.1.8 Door operations. Except as specifically permitted
by this section egress doors shall be readily openable from
the egress side without the use of a key or special knowledge
or effort.

____Remove keyed lock from front door.
____Red button on front door considered special knowledge. Door needs to open without pressing a button.
10/07/2008 VIOL - MEANS OF EGRESS Violation 1028.8 Panic hardware. Where panic hardware is installed,
the panic or fire exit hardware shall be the only locking
device on the door.

____Remove the thumb-turn lock from door in TV room. No other locks allowed on doors with panic hardware.
10/07/2008 VIOL - MEANS OF EGRESS Violation 1028.4 Exit signs. Exit signs shall be installed and maintained
in accordance with Section 1011. Decorations, furnishings,
equipment or adjacent signage that impairs the visibility of exit
signs, creates confusion or prevents identification of the exit
shall not be allowed.

____Remove Exit sign from South side door on 2nd floor. This is not an Exit.