Inspection History Details
Inspection Status: Approved
Inspection History: VIOL - MEANS OF EGRESS
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/17/2008 | VIOL - MEANS OF EGRESS | Approved | ||
| 09/23/2008 | VIOL - MEANS OF EGRESS | Violation | 1027.4 Power source. Where emergency illumination is required in Section 1027.5, exit signs shall be visible under emergency illumination conditions. ____Repair Exit sign. Rear Exit to parking lot. |
|
| 09/23/2008 | VIOL - MEANS OF EGRESS | Violation | 1027.5 Illumination emergency power. The power supply for means of egress illumination shall normally be provided by the premises’ electrical supply. In the event of power supply failure, illumination shall be automatically provided from an emergency system... ____Repair emergency lighting unit in computer room. |
|
| 09/23/2008 | VIOL - MEANS OF EGRESS | Violation | 1008.1.8 Door operations. Except as specifically permitted by this section egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. ____Remove double-keyed deadbolt from main door and kitchen exit. Thumb-turn deadbolt lock or panic hardware allowed. |
|
| 09/23/2008 | VIOL - MEANS OF EGRESS | Violation | 1028.3 Obstructions. A means of egress shall be free from obstructions that would prevent its use... ____Remove ladders obstructing means of egress in front courtyard and on second floor balcony exit. ____Remove trash from hallway obstructing exit near bedroom #18. |
|
| 09/23/2008 | VIOL - MEANS OF EGRESS | Violation | 1008.2 Gates. Gates serving the means of egress system shall comply with the requirements of this section. Gates used as a component in a means of egress shall conform to the applicable requirements for doors. ____Remove locks from courtyard gates. These gates are components in the means of egress. They need to be outfitted with locks that do not require a key or special knowledge. |