Case: T08FR02840

Parcel: 13331159E


Addresses:

8730 E BROADWAY BL


Inspection Status: Approved

Inspection History: INSP - FULL

Case Number - T08FR02840

Inspection Description - INSP - FULL

Inspection Status - Approved

Date Description Inspector Results Comments
11/07/2008 INSP - FULL Approved All violations are corrected; no other hazards noted at this time.
09/19/2008 INSP - FULL Violation 907.20.1 Maintenance required. Whenever or wherever any device, equipment, system, condition, arrangement, level of protection or any other feature is required for compliance with the provisions of this code, such device, equipment, system, condition, arrangement, level of protection or other feature shall thereafter be continuously maintained in accordance with applicable NFPA requirements or as
directed by the fire code official. You will have the missing escussion plate replaced on sprinkler head in mens restroom.
09/19/2008 INSP - FULL Violation IFC 1014.4.1 Nonpublic aisles serving less than 50 people must be no less than 28 inches wide at all times. Maintain aisles in stock room to minimum of 28 inches where they do not serve as part of the main exit.
09/19/2008 INSP - FULL Violation 315.2.1 Ceiling clearance. Storage shall be maintained 2 feet (610 mm) or more below the ceiling in nonsprinklered areas of buildings or a minimum of 18 inches (457 mm) below sprinkler head deflectors in sprinklered areas of buildings. Remove excess stock on toy aisle to allow 18 inches in all directions for sprinkler heads.
09/19/2008 INSP - FULL Violation 1006.1 Illumination required. The means of egress, including the exit discharge, shall be illuminated at all times the building space served by the means of egress is occupied. Cause your emergency lighting in the pharmacy hallway to light.
09/19/2008 INSP - FULL Violation 3003.5.3 Securing compressed gas containers, cylinders and tanks. Compressed gas containers, cylinders and tanks shall be secured to prevent falling caused by contact, vibration or seismic activity. Secure your helium tanks in stock room.
09/19/2008 INSP - FULL Violation 907.20.5 Maintenance, inspection and testing. The building owner shall be responsible for ensuring that the fire and life safety systems are maintained in an operable condition at all times. Service personnel shall meet the qualification requirements of NFPA 72 for maintaining, inspecting and testing such systems. A written record shall be maintained and shall be made available to the fire code official. Have your sprinkler system and all fire extinguishers tested and tagged. Submit sprinkler inspection report to Fire Prevention ( fax: 791-5346 ATTN: Nikki Sprenger) Your systems are required to be tested by the end of this month to avoid a violation of the fire code.
09/17/2008 INSP - FULL Violation 605.5 Extension cords. Extension cords and flexible cords shall not be a substitute for permanent wiring. Remove all extension cords in use. (Noted: behind front checkout, developing room, breakroom, )
09/17/2008 INSP - FULL Violation 906.6 Unobstructed and unobscured. Portable fire extinguishers shall not be obstructed or obscured from view.
09/17/2008 INSP - FULL Violation 605.3Working space and clearance. A working space of not less than 30 inches (762 mm) in width, 36 inches (914 mm) in depth and 78 inches (1981 mm) in height shall be provided in front of electrical service equipment. Remove all objects blocking your electrical panels in your stock room.