Case: T08FR02722

Parcel: 11615077H

Inspection Status: Correction Required

Inspection History: VIOL - MEANS OF EGRESS

Case Number - T08FR02722

Inspection Description - VIOL - MEANS OF EGRESS

Inspection Status - Correction Required

Date Description Inspector Results Comments
09/09/2008 VIOL - MEANS OF EGRESS Correction Required 1008.1.8.5 Unlatching.
The unlatching of any door or leaf shall not require more than one operation.

_____ The back south east egress door located in the kitchen has a secondary locking device that shall be disabled or removed.

1008.1.9 Panic and fire exit hardware.
Where panic and fire exit hardware is installed, it shall comply with the following:
1. The actuating portion of the releasing device shall extend at least one-half of door leaf width.
2. The maximum unlatching force shall not exceed 15 pounds (67 N).
3. No additional locks or latches shall be added

_____ Remove the turn knob with locking device from the north east door as no additonal locks shall be allowed to added to a door with panic hardware.