Inspection History Details
Inspection Status: Correction Required
Inspection History: VIOL - MEANS OF EGRESS
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/04/2008 | VIOL - MEANS OF EGRESS | Correction Required | TFC 1008.1.8 Door operations. Except as specifically permitted by this section egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. _____1.Remove the loss prevention chain and locking hardware from the exit doors. _____2.Remove the padlock and locking hardware from the north egress door located in the garden center. _____3.Remove the padlock, locking bar and deouble-keyed lock from the Northeast egress door located in receiving. NOTE:Replace the double-keyed lock with a thumb-turn lock. |
|
| 09/04/2008 | VIOL - MEANS OF EGRESS | Correction Required | TFC 1008.1.8.3 Locks and latches. Locks and latches shall be permitted to prevent operation of doors the following exists. 2.2. A readily visible durable sign is posted on the egress side on or adjacent to the door stating: THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED. The sign shall be in letters 1 inch (25 mm) high on a contrasting background. _____1.Post the above wording above the inside of the entrance/exit doors. |
|
| 09/04/2008 | VIOL - MEANS OF EGRESS | Correction Required | TFC 1008.1.8.4 Bolt locks. Manually operated flush bolts or surface bolts are not permitted. _____1.Remove the suface bolt from the beer cooler door. |