Case: T08FR02103

Parcel: 10607010A


Addresses:

1109 W PRINCE RD


Inspection Status: Correction Required

Inspection History: VIOL - MEANS OF EGRESS

Case Number - T08FR02103

Inspection Description - VIOL - MEANS OF EGRESS

Inspection Status - Correction Required

Date Description Inspector Results Comments
07/23/2008 VIOL - MEANS OF EGRESS Correction Required TFC 1028.2 Reliability. Required exit accesses, exits or exit discharges
shall be continuously maintained free from obstructions
or impediments to full instant use in the case of fire or
other emergency when the areas served by such exits are occupied.
Security devices affecting means of egress shall be subject
to approval of the fire code official.

_____1. Remove all merchandise storage from obstructing the Northwest egress door.
07/23/2008 VIOL - MEANS OF EGRESS Correction Required TFC 1008.1.8.5 Unlatching. The unlatching of any door or
leaf shall not require more than one operation.

_____1. Remove 1 of the 2 thumb-turn locks from the Southwest egress door.

_____2. Remove 1 of the 2 thumb-turn locks from the Southeast egress doors.
07/23/2008 VIOL - MEANS OF EGRESS Correction Required TFC 1027.3 Exit sign illumination. Exit signs shall be internally or
externally illuminated. The face of an exit sign illuminated
from an external source, shall have an intensity of not less than
5 foot-candles (54 lux). Internally illuminated signs shall provide
equivalent luminance and be listed for the purpose.



_____1. The exit sign located above the Southeast exit door shall be illuminated at all times.