Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Case: T08FR01643

Parcel: 107143400


Addresses:

307 E GRANT RD


Inspection Status: Correction Required

Inspection History: VIOL - FLAMMABLE LIQUIDS

Case Number - T08FR01643

Inspection Description - VIOL - FLAMMABLE LIQUIDS

Inspection Status - Correction Required

Date Description Inspector Results Comments
06/18/2008 VIOL - FLAMMABLE LIQUIDS Correction Required 3404.4.2.4 Storage adjacent to buildings.
A maximum of 1,100 gallons (4163 L) of liquids stored in closed containers and portable tanks is allowed adjacent to a building located on the same premises and under the same management, provided that:
1. The building does not exceed one story in height. Such building shall be of fire-resistance-rated construction with noncombustible exterior surfaces or noncombustible construction and shall be used principally for the storage of liquids; or
2. The exterior building wall adjacent to the storage area shall have a fire-resistance rating of not less than 2 hours, having no openings to above-grade areas within 10 feet (3048 mm) horizontally of such storage and no openings to below-grade areas within 50 feet (15 240 mm) horizontally of such storage.

3404.4.4 Security.
Storage areas shall be protected against tampering or trespassers by fencing or other approved control measures.

3404.4.6 Clearance from combustibles.
The storage area shall be kept free from weeds, debris and combustible materials not necessary to the storage. The area surrounding an exterior storage area shall be kept clear of such materials for a minimum distance of 15 feet (4572 mm).

_____ You are over the maximum allowed 30 gallons permitted for your oil based paint. You must remove, dipose, and/or place your excess piant in seperate room according to the codes stated above.

*** There is no limitation on storage for water-based paint

*** If a storage room is choosen, then proper security and clearance from combustibles shall be followed. I.E A lock shall be placed on the storage room and the yard shall be maintained.




________________________________________________
(Joseph P. Longo, Inspector, Tucson Fire Department)

I, ______________________ have received a copy of this inspection report.
(Building Representative)

______________________________
(Captain)

Full inspection done by Inspector Joseph P. Longo
Re-inspection scheduled on or after ___/___/___
Call Inspector Longo at 235-4262 or 791-4502, if you have any further questions.
Thank you.

Re-inspection passed:

______________________
Joseph P. Longo