Inspection History Details
Inspection Status: Approved
Inspection History: INSP - FULL
Case Number - T08FR01380
Inspection Description - INSP - FULL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/30/2008 | INSP - FULL | Approved | ||
06/02/2008 | INSP - FULL | Correction Required | The Tucson Fire Department has conducted a fire safety inspection at the above stated business . Below is a list of violations that shall be corrected to provide compliance with the applicable codes, regulations and ordinances. Compliance is required by the 2006 International Fire Code (with modifications). ___1. PROBLEM: Compressed gas cylinder in main office is unsecured. TFC REFERENCE: 3003.5.3 Securing compressed gas containers, cylinders and tanks. Compressed gas containers, cylinders and tanks shall be secured to prevent falling caused by contact, vibration or seismic activity. REQUIRED CORRECTION: Properly secure compressed gas tank. ___2. PROBLEM: Main entrance to office has double key lock and has no sign indicating that door is to remain unlocked while building is occupied. TFC REFERENCE: 1008.1.8.3 Locks and latches. Locks and latches shall be permitted to prevent operation of doors where any of the following exists: 2.2. A readily visible durable sign is posted on the egress side on or adjacent to the door stating: THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED. The sign shall be in letters 1 inch (25 mm) high on a contrasting background, REQUIRED CORRECTION: Have above mentioned sign posted above main entrance door. ___3. PROBLEM: Fire extinguishers tags are out of date. TFC REFERENCE: 901.6 Inspection, testing and maintenance. Fire detection, alarm and extinguishing systems shall be maintained in an operative condition at all times, and shall be replaced or repaired where defective. Nonrequired fire protection systems and equipment shall be inspected, tested and maintained or removed. REQUIRED CORRECTION: Either have portable fire extinguishers serviced or remove from premises. ___4. PROBLEM: Hole in ceiling in fitness room and holes in walls behind dryer in laundry room on far west side and in small room behind laundry near main office. TFC REFERENCE: 703.1 Maintenance. The required fire-resistance rating of fire-resistance-rated construction (including walls, firestops, shaft enclosures, partitions, smoke barriers, floors, fire-resistive coatings and sprayed fire-resistant materials applied to structural members and fire-resistant joint systems) shall be maintained. Such elements shall be properly repaired, restored or replaced when damaged, altered, breached or penetrated. Openings made therein for the passage of pipes, electrical conduit, wires, ducts, air transfer openings and holes made for any reason shall be protected with approved methods capable of resisting the passage of smoke and fire. REQUIRED CORRECTION: Have holes in ceiling and walls properly repaired. ___5. PROBLEM: Material Safety Data Sheets on pool chemicals unavailable for inspection. TFC REFERENCE: 407.2 Material Safety Data Sheets. Material Safety Data Sheets (MSDS) for all hazardous materials shall be readily available on the premises. REQUIRED CORRECTION: Have MSDS readily available for inspection. ___6. PROBLEM: Pool chemicals stored outside in exposed to the elements and sunlight. TFC REFERENCE: 2701.3.3.6 Protection of hazardous materials. Safeguards shall be provided to minimize the risk of exposing hazardous materials to a fire or physical damage whereby such exposure could endanger or lead to the endangerment of people or property. REQUIRED CORRECTION: Store pool chemicals in a safe location unexposed to the elements. ___7. PROBLEM: Certificate of Occupancy not readily available for inspection. TFC REFERENCE: 105.3.5 Posting the permit. Issued permits shall be kept on the premises designated therein at all times and shall be readily available for inspection by the fire code official. REQUIRED CORRECTION: Have C of O posted and visble. RECOMMENDATION: When I inspected the pool gates they functioned properly ( I.e. the closed properly ) but apparently someone closed gate but did not allow the catch to engage. Be sure these gates are checked from regularly to make sure they are properly latched as young children could easily wander into the pool area. The Tucson Fire Department is committed to the protection of your property and your life safety.Your help as a business owner and as a citizen is greatly appreciated. Property Representative Signature: _________________________. Fire Inspector Signature: _________________________(791-4502). Reinspection Date: ___/___/___ or later. _X__Approved ___Not Approved |