Inspection History Details
Inspection Status: Approved
Inspection History: INSP - FULL
Case Number - T08FR01226
Inspection Description - INSP - FULL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/30/2008 | INSP - FULL | Approved | ||
05/14/2008 | INSP - FULL | Correction Required | The Tucson Fire Department has conducted a fire safety inspection at the above stated business . Below is a list of violations that shall be corrected to provide compliance with the applicable codes, regulations and ordinances. Compliance is required by the 2006 International Fire Code (with modifications). ___1. PROBLEM: Electrical room needs sign identifying it as such. TFC REFERENCE: 605.3.1 Labeling. Doors into electrical control panel rooms shall be marked with a plainly visible and legible sign stating ELECTRICAL ROOM or similar approved wording. REQUIRED CORRECTION: Have sign placed on electrical room door. ___2. PROBLEM: Storage in front of electrical panels. TFC REFERENCE: 605.3Working space and clearance. A working space of not less than 30 inches (762 mm) in width, 36 inches (914 mm) in depth and 78 inches (1981 mm) in height shall be provided in front of electrical service equipment. Where the electrical service equipment is wider than 30 inches (762 mm), the working space shall not be less than the width of the equipment. No storage of any materials shall be located within the designated working space. REQUIRED CORRECTION: Provide required clearance around electrical panels. ___3. PROBLEM: Break room has power cube used in outlet. TFC REFERENCE: 605.4 Multiplug adapters. Multiplug adapters, such as cube adapters, unfused plug strips or any other device not complying with the ICC Electrical Code shall be prohibited. REQUIRED CORRECTION: Plug appliances directly into outlet or use approved GFI power strip. ___4. PROBLEM: Need sign on outside door leading to sprinkler system riser room indicating it as such. TFC REFERENCE: 510.1 Identification. Fire protection equipment shall be identified in an approved manner. Rooms containing controls for air-conditioning systems, sprinkler risers and valves, or other fire detection, suppression or control elements shall be identified for the use of the fire department. Approved signs required to identify fire protection equipment and equipment location, shall be constructed of durable materials, permanently installed and readily visible. REQUIRED CORRECTION: Have durable sign placed on outside of outside sprinkler riser room door. ___5. PROBLEM: Some storage noted around base of sprinkler riser. TFC REFERENCE: 508.5.4 Obstruction. Posts, fences, vehicles, growth, trash, storage and other materials or objects shall not be placed or kept near fire hydrants, fire department inlet connections or fire protection system control valves in a manner thatwould prevent such equipment or fire hydrants from being immediately discernible. The fire department shall not be deterred or hindered from gaining immediate access to fire protection equipment or fire hydrants. REQUIRED CORRECTION: Keep area around sprinkler riser clear of storage. ___6. PROBLEM: Power strip behind front counter is plugged into an orange extension cord and power strip is plugged into extension cord behind frozen bar case. TFC REFERENCE: 605.4.2 Power supply. Relocatable power taps shall be directly connected to a permanently installed receptacle. REQUIRED CORRECTION: Plug power strips directly into electrical receptacle. May need to use power strips with longer cords ___7. PROBLEM: Three pop down sprinkler heads are missing covers under outside over hang. TFC REFERENCE: 901.6 Inspection, testing and maintenance. Fire detection, alarm and extinguishing systems shall be maintained in an operative condition at all times, and shall be replaced or repaired where defective. REQUIRED CORRECTION: Have qualified individual replace covers on pop down sprinkler heads. The Tucson Fire Department is committed to the protection of your property and your life safety.Your help as a business owner and as a citizen is greatly appreciated. Property Representative Signature: _________________________. Fire Inspector Signature: _________________________(791-4502). Reinspection Date: ___/___/___ or later. __X_Approved ___Not Approved |