Inspection History Details
Inspection Status: Approved
Inspection History: INSP - FULL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/14/2008 | INSP - FULL | Approved | ||
| 03/25/2008 | INSP - FULL | Correction Required | The Tucson Fire Department has conducted a fire safety inspection at the above stated business . Below is a list of violations that shall be corrected to provide compliance with the applicable codes, regulations and ordinances. Compliance is required by the 2006 International Fire Code (with modifications). ___1.PROBLEM: Orange extension cord used for radio in office and another orange extension cord leading into freezer. TFC REFERENCE: 605.5 Extension cords. Extension cords and flexible cords shall not be a substitute for permanent wiring. REQUIRED CORRECTION: Appliances must be plugged directly into electrical outlet or into approved GFI power strip. Extension cords are not to be used. ___2. PROBLEM: Power strip is plugged into grey extension cord. TFC REFERENCE: 605.4.2 Power supply. Relocatable power taps shall be directly connected to a permanently installed receptacle. REQUIRED CORRECTION: Power strip must be directly plugged into outlet. ___3. PROBLEM: Open light socket above oven. TFC REFERENCE: 605.6 Unapproved conditions. Open junction boxes and open-wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. REQUIRED CORRECTION: Put proper light bulbs into open light sockets or insert a cap. ___4. PROBLEM: Cube adapter used in office and an orange one used under front counter. TFC REFERENCE: 605.4 Multiplug adapters. Multiplug adapters, such as cube adapters, unfused plug strips or any other device not complying with the ICC Electrical Code shall be prohibited. REQUIRED CORRECTION: Plug appliances directly into outlet or use approved GFI power strip. ___5. PROBLEM: Certificate of Occupancy not available for viewing. TFC REFERENCE:105.3.5 Posting the permit. Issued permits shall be kept on the premises designated therein at all times and shall be readily available for inspection by the fire code official. REQUIRED CORRECTION: Have Certificate of Occupancy posted for viewing by fire code official. The Tucson Fire Department is committed to the protection of your property and your life safety. Your help as a business owner and as a citizen is greatly appreciated. Property Representative Signature: _________________________. Fire Inspector Signature: _________________________(791-4502). Reinspection Date: ___/___/___ or later. _X__Approved ___Not Approved |