Inspection History Details
Inspection Status: Approved
Inspection History: INSP - FULL
Case Number - T08FR00762
Inspection Description - INSP - FULL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/09/2008 | INSP - FULL | Approved | ||
03/18/2008 | INSP - FULL | Correction Required | The Tucson Fire Department has conducted a fire safety inspection at the above stated business . Below is a list of violations that shall be corrected to provide compliance with the applicable codes, regulations and ordinances. Compliance is required by the 2006 International Fire Code (with modifications). ___1. PROBLEM: Cube adapter used under cash register TFC REFERENCE: 605.4 Multiplug adapters. Multiplug adapters, such as cube adapters, unfused plug strips or any other device not complying with the ICC Electrical Code shall be prohibited. REQUIRED CORRECTION: Plug appliances directly into outlet or use approved power strip. ___2. PROBLEM: Secure power strip behind the desk. TFC REFERENCE: 605.4.3 Installation. Relocatable power tap cords shall not extend through walls, ceilings, floors, under doors or floor coverings, or be subject to environmental or physical damage. REQUIRED CORRECTION: Secure power strip so that it is not hanging by weight of plugs. ___3. PROBLEM: Certificate of Occupancy not posted. TFC REFERENCE: 105.3.5 Posting the permit. Issued permits shall be kept on the premises designated therein at all times and shall be readily available for inspection by the fire code official. REQUIRED CORRECTION: Have C of O Posted for inspection by fire official. ___4. PROBLEM: Make sure sliding gate on outside exit is locked in open position to prevent inadvertant closing and/or locking thus preventing unobstructed exit. TFC REFERENCE: 1003.6 Means of egress continuity. The path of egress travel along a means of egress shall not be interrupted by any building element other than a means of egress component as specified in this chapter. REQUIRED CORRECTION: Sliding door on outside gate shall be locked in open position while building is occupied. The Tucson Fire Department is committed to the protection of your property and your life safety. Your help as a business owner and as a citizen is greatly appreciated. Property Representative Signature: _________________________. Fire Inspector Signature: _________________________(791-4502). Reinspection Date: ___/___/___ or later. _X__Approved ___Not Approved |