Permit: T08EL02158

Parcel: 116191520


Addresses:

3 N BONITA AV #01

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
05/29/2009 ELECTRIC - FINAL Approved IVRS - Inspection :*
05/18/2009 ELECTRIC - FINAL Not ready for Inspection IVRS - Inspection :*
1) RECALL ONCE POWER IS ON FOR FINAL
02/18/2009 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) CONTRACTOR HAS ASKED FOR TEMP POWER FOR CONSTRUCTION. I TALKED TO R. MAJUTA, ABOUT THIS HE DECLINED DUE TO NEW SERVICE PANEL HAS NO RECORD OF PERMITS. NEW SERVICE NEEDS TO BE PERMITTED AND INSPECTED
11/19/2008 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) OMIT HAZARDOUS WIRING REAR PORCH LIGHT FIXTURE AND OUTLET
2) PROVIDE 1" CLEARANCE WATER HEATER B-VENT FROM PORCH COMBUSTIBLES EXTEND PRESSURE RELIEF VALVE 6" FROM GROUND PLATFORM HAZARDOUS
3) PANEL NOT GROUNED
4) WEATHERED FIXTURE REAR DOOR
5) WINDOWS IN BEDROOMS MUST OPERATE FREELY
6) CHANGED OUTLETS FROM 2 WIRE TO GROUNDED
7) HAZARDOUS ELECTRICAL WIRE TO TO REAR ROOM CEILING FAN
8) GFCI PROTECT KITCHEN COUNTER OUTLETS