Inspection History Details
Inspection Status: Not ready for Inspection
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/18/2009 | ELECTRIC - FINAL | Not ready for Inspection | ||
| 08/17/2009 | ELECTRIC - FINAL | Denied | 1) INSTALL DBL POLE 20A CIRCUIT BREAKER AT MAIN AND SIDE DISCONNECTS 2) AT MAIN TIE GROUND TO NUETRAL BAR, THEN JUMP BACK TO GROUND BAR 3) PHYSICALLY PROTECT WIRING AT DIAMETER BY O/S DOOR 4) INSTALL LOCK NUT AND 2 1/2" X 3/4" REDUCING WASHERS 5) CLEAR AREA IN FRONT OF MAIN |
|
| 11/13/2008 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) WEATHERED FRONT LIGHT FIXTURE 2) SEAL EXTERIOR DISCONNECT AND PANEL KNOCKOUTS 3) MISSING DEAD FRONT MAIN SERVICE PANEL 4) MISSING COVER PLATES THROUGHOUT 5) GFCI PROTECT KITCHEN COUNTER OUTLETS 6) SMOKE ALARM BEDROOMS 7) GFCI PROTECT OUTLET BATHROOM LIGHT FIXTURE OR REPLACE 8) PROVIDE PROOF OF PERMIT REAR ADDITIONS 9) EXPOSED WIRING INTERIOR FIXTURES 10) POST HOUSE NUMBERS |