Inspection History Details
Inspection Status: Denied
Inspection History: ELECTRIC - RECONNECT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/07/2008 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999* NOTES 1, 2, 4, 5, 6 RELOCATE SMOKE DETECTORS MINIMUM 36" FROM FORCED AIR REGISTERS |
|
| 10/31/2008 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) POST HOUSE NUMBERS 2) MANY ADDED CIRCUITS TO PANEL PROVIDE PROOF OF PERMIT A/C ROOF TOP 220 LAUNDRY 3) SEAL SERVICE KNOCKOUTS 4) OVERLOADED PANEL UPGRADE POSSIBLE 5) PROVIDE LISTED DEAD FRONT/REMOVE SHART POINT SCREW FROM DEAD FRONT 6) PROVIDE PROOF ALL ATTACHED ADDITION PERMITS 7) ALL EXTERIOR OUTLETS WEATHERED 8) EXPOSED WIRING EXTERIOR 9) SMOKE DETECTORS BEDROOMS 10) 2 WIRE PLUGS CHANGED ? GROUND GFCI PROTECT HEAD OF CIRCUIT OR INSTALL 2 WIRE PLUGS |