Inspection Status: Approved
Inspection History: ELECTRIC - RECONNECT
Permit Number - T08EL02058
Inspection Description - ELECTRIC - RECONNECT
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/08/2009 | ELECTRIC - RECONNECT | Approved | IVRS - Inspection :* | |
02/04/2009 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999* ITEM #1, 2, 3, 5, 6, 8 1. ALL EXT. RECEPTACLES MUST BE GFI PROTECTED 2. NEED TO INSTALL SMOKE DETECTORS IN BEDROOMS AND HALLWAYS 3. ALL RECEPTACLES AT KITCHEN COUNTER SPACE AND BATHROOM NEED TO BE GFI PROTECTED 4. ADDITION AT BACK OF HOUSE DOESN'T MEET EGRESS, OWNER WILL DEMOLISH AND BRING UP TO CODE 5. TRP WATER LINE, NEEDS TO TERMINATE IN A WASTE RECEPTOR PAN OR GRAVITY FLOW TO OUTSIDE OF HOUSE 6. BUBBLE COVERS ON ALL EXT. RECEPTACLES, NOT PROTECTED BY EAVES - 45 DEG. ANGLE 7. BOND GAS AND WATER LINES 8. WILL NEED TO GROUND SERVICE PANEL TO 2-GROUND RODS 6' APART WITH A CONTINUOUS COPPER WIRE TO PANEL 9. NEED TO SHOW PERMITTED WORK DONE ON CARPORT ENCLOSURE TO A ROOM WITH A FULL BATH 10. CARPORT - NOT STRUCTURALLY SOUND |
|
11/03/2008 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999* |