Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T08EL02058

Parcel: 12517057A


Addresses:

3849 E CALLE ALTAR


Inspection Status: Approved

Inspection History: ELECTRIC - RECONNECT

Permit Number - T08EL02058

Inspection Description - ELECTRIC - RECONNECT

Inspection Status - Approved

Date Description Inspector Results Comments
04/08/2009 ELECTRIC - RECONNECT Approved IVRS - Inspection :*
02/04/2009 ELECTRIC - RECONNECT Denied IVRS - Inspection :
See detailed listing on site.| 999*
ITEM #1, 2, 3, 5, 6, 8

1. ALL EXT. RECEPTACLES MUST BE GFI PROTECTED
2. NEED TO INSTALL SMOKE DETECTORS IN BEDROOMS AND HALLWAYS
3. ALL RECEPTACLES AT KITCHEN COUNTER SPACE AND BATHROOM NEED TO BE GFI PROTECTED
4. ADDITION AT BACK OF HOUSE DOESN'T MEET EGRESS, OWNER WILL DEMOLISH AND BRING UP TO CODE
5. TRP WATER LINE, NEEDS TO TERMINATE IN A WASTE RECEPTOR PAN OR GRAVITY FLOW TO OUTSIDE OF HOUSE
6. BUBBLE COVERS ON ALL EXT. RECEPTACLES, NOT PROTECTED BY EAVES - 45 DEG. ANGLE
7. BOND GAS AND WATER LINES
8. WILL NEED TO GROUND SERVICE PANEL TO 2-GROUND RODS 6' APART WITH A CONTINUOUS COPPER WIRE TO PANEL
9. NEED TO SHOW PERMITTED WORK DONE ON CARPORT ENCLOSURE TO A ROOM WITH A FULL BATH
10. CARPORT - NOT STRUCTURALLY SOUND
11/03/2008 ELECTRIC - RECONNECT Denied IVRS - Inspection :
See detailed listing on site.| 999*