Inspection History Details
Inspection Status: Partial Approval
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/05/2008 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection :* 1) UNIT 2 EXTERIOR FIXTURE MUST BE FOR EXTERIOR USE WEATHERED 2) RECALL 02090 |
|
| 10/31/2008 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* UNIT 3: 1) GFCI PROTECT BATH AND KITCHEN OUTLETS 2) PROVIDE PROOF OF PERMIT ADDED CIRCUIT TO WINDOW A/C UNIT 3) 2 WIRE CIRCUIT GFCI HEAD OF CIRCUIT OR REPLACE 2 WIRE RECEPTACLE UNIT 2: 1) PERMIT ADDED CIRCUIT A/C WINDOW UNIT 2) WEATHERED FIXTURE EXTERIOR 3) OMIT LAMP CORD FIXTURE LIVING ROOM CEILING 4) CHANGED 2 WIRE OUTLETS GFCI PROTECT HEAD CIRCUIT 5) GFCI BATH OUTLET |
|
| 10/30/2008 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) UNIT #2: GFI'S IN KITCHEN OUTLETS 2) SMOKE DETECTOR IN STUDIO ROOM 3) UNIT #3: SAME AS ABOVE |