Permit: T08EL01902

Parcel: 115023960


Addresses:

321 E LEE ST

Inspection Status: Not ready for Inspection

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
10/14/2008 ELECTRIC - FINAL Not ready for Inspection IVRS - Inspection :*
1) MOVE SMOKE DETECTORS AT LEAST 3' FROM A/C REGISTERS
2) RECALL FOR FINAL AFTER POWER IS RESTORED, TO CHECK FUNCTION OF GFI'S AND SMOKEY LOCATIONS
10/06/2008 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NO ACCESS
2) CALLED NUMBER LEFT ON MESSAGE AT 10:25 AM AND NO ANSWER OR NO VOICEMAIL
2) NEED GFI RECEPTS AT KITCHEN COUNTER
3) SMOKIES ARE REQUIRED IN ALL BEDROOMS
4) DRYER VENT EXHAUST WILL REQUIRE A COVER WITH A FLAPPER DOOR
5) TPR LINE ON H20 HEATER MUST TERMINATE TO THE OUTSIDE AND BE INDEPENDENT
6) ELECTRICAL DIMMER KNOB MUST HAVE COVER PLATE
7) WAS ADDITION PERMITTED ?
8) NEED 2 GROUND RODS 6' APART WITH CONTINOUS GROUND WIRE
9) NEED TO BOND GAS AND WATER
10) ELECTRIC WIRES COVERED WITH STUCCO, MUST BE CONDUIT OR EXT. WIRE TYPE FOR MASONRY INSTALLATION