Permit: T08EL01893

Parcel: 141136190


Addresses:

7498 S GIACHERY AV


Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Permit Number - T08EL01893

Inspection Description - ELECTRIC - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
11/25/2008 ELECTRIC - FINAL Approved IVRS - Inspection :*
10/17/2008 ELECTRIC - FINAL Not ready for Inspection IVRS - Inspection :*
SEE LAST INSPECTION.
GET APPROVAL FOR POOL ENCLOSURE REQUIREMENT BEFORE RECONNECT CAN BE OK'd
10/10/2008 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SEE ITEMS LAST INSPECTION
2) CEILING FAN BOX INSTALLED HALL BEDROOM, NOT DONE PER CODE MISSING BOND TO METAL BOX ROMEX CONNECTOR, REQUIRES A COVER, WIRE NUTS
3) SPA/POOL SUB PANEL HOLE K/O IN BOX NEEDS A PLUG
4) I HAVE LEFT A COPY OF THE POOL BARRIER REQUIREMENTS FROM THE ORIGINAL SITE PLAN WHEN THE POOL WAS INSTALLED. THE 4' BARRIER BETWEEN HOUSE AND POOL HAS BEEN REMOVED. THE 5'-0" REQUIRED AT EXT. IS NO LONGER 5'-0". WINDOWS INSIDE POOL AREA TO BE SECURE WITH NON-REMOVABLE SCREW, AT 4" MAX OPENING
5) THIS POOL COMPLAINT WILL BE TURNED OVER TO DEPT OF NEIGHBORHOOD RESOURCES
10/07/2008 ELECTRIC - FINAL Not ready for Inspection IVRS - Inspection :*
1) #8 AL. WIRE FOR A/C UNIT ON 60/60 AMP BREAKER CHANGE TO 40 OR 50 AMP
2) CAN'T OPEN COMBINATION-NEED TO INSPECTION INSIDE WITH CODE GIVEN
3) PLUG HOLE BOTTOM OF SERVICE