Permit: T08EL01849

Parcel: 13004050A

Inspection Status: Partial Approval

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
10/14/2008 ELECTRIC - FINAL Partial Approval IVRS - Inspection :*
1) PENDING CARPORT
09/24/2008 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) CONFIRM THAT CARPORT EXTENDED TO WEST SIDE WAS PERMITTED AND INSPECTED
2) 2 GROUND RODS REQUIRED AT SERVICE PANEL 6' APART
3) BOND GAS LINE
4) OUTLETS AT KITCHEN COUNTER AND BATHROOM SHALL BE GFI PROTECTED
5) SMOKE ALARMS REQUIRED IN EACH BEDROOM AND HALL
6) GAS FLEX SHALL NOT PENETRATE FURNACE COMPARTMENT CAVITY