Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/16/2008 | ELECTRIC - FINAL | Approved | PER JBURGE ON T08OT02431 AND PER BETH GRANT | |
| 09/17/2008 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection :* A CERTIFICATE OF OCCUPANCY IS REQUIRED TO USE THIS SPACE. THE C OF O MUST BE FOR A TEMPLE PLEASE CONTACT THE ZONING ADMINISTRATOR TO SEE IF THIS IS AN ALLOWED USE. 1. WATER HEATER TPRV IS INCORRECT 2. JUSTIFY PLUMBING FIXTURE COUNT 3. PROVIDE FLOOR PLANS 4. OBTAIN C OF O |
|
| 09/11/2008 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. GROUNDING ELECTRODE CONDUCTOR NEEDS TO BE PROPERLY REPAIRED. NEED IRREVERSIBLE CLAMP OR EXOTHERMIC WELD 2. INSTALL SMOKE DETECTOR IN SLEEPING AREAS AND OUTSIDE SLEEPING AREAS PER INSTRUCTIONS 3. KITCHEN COUNTER RECEPTACLES TO BE GFI PROTECTED 4. ADJUST PANEL INTERIOR TO BE FLUSH WITH DEAD FRONT 5. BLANK OPEN BREAKER POSITION 6. STRAP MC CABLE TO WATER HEATER 7. BATHROOM RECEPTACLES TO BE GFI PROTECTED 8. NEED PROPER WARNING CLEARANCE IN FRONT OF PANEL 9. GROUNDS & NEUTRALS TO BE SEPARATE IN PANELS |