Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/28/2008 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
| 10/21/2008 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection :* 1) REPLACE BOND WIRE TO WATER PIPE |
|
| 10/10/2008 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection :* 1) 30-DAY RECONNECT 2) IDENTIFY ALL BREAKERS IN PANEL 3) IDENTIFY NEUTRAL IN SUB PANEL WITH WHITE TAPE ON BOTH ENDS |
|
| 10/08/2008 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) #4 COPPER GOOD FOR 85 AMPS NOT 100 2) 2 BREAKERS MAIN PANEL ARE DBL LUGGED 3) #14 WIRE ON 20 AMP BREAKER |
|
| 09/09/2008 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NEED LICENSED ELECTRICIAN TO CORRECT ALL DEFICIENCIES IN 3 EAST SIDE ELECTRIC PANELS AND CARPORT OUTLET 2) NEED SMOKE DETECTORS INSTALLED PER CODE AND MANUFACTURERS SPECS IN ALL BEDROOMS AND HALLWAY 3) NEED GFI PROTECTION FOR KITCHEN COUNTER OUTLETS AND BATH OUTLETS |