Inspection History Details
Inspection Status: Denied
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/13/2009 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) EXPOSE GROUNF RODS (2-MIN) TO ELECTRIC SERVICE 2) BUBBLE COVERS REQUIRED AT ALL EXTERIOR OUTLETS AND SHALL BE GFI PROTECTED 3) BOND GAS LINE 4) GFI PROTECTED OUTLETS REQUIRED IN KITCHEN 5) SMOKE ALARM REQUIRED IN EACH BEDROOM AND OUTSIDE EACH BEDROOM |
|
| 09/03/2008 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PROVIDE ACCESS INTO BLDG FOR INSPECTIONS 2) NO CONTACT NUMBER LEFT ON IVR 3) NEED TO REPLACE DEAD FACE COVER AT SUB PANEL 4) RECALL WHEN READY |
|
| 09/02/2008 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PROVIDE WEATHERED COVER EXTERIOR SUB PANEL 2) REPLACE DEAD FRONT SCREWS WITH SCREWS WITH NO SHARP POINTS 3) LABEL CIRCUITS DEAD FRONT 4) PROVIDE WATER AND GAS BONDS 5) PROVIDE ACCESS TO UNIT 6) PROVIDE PROOF OF PERMIT FOR STRUCTURES ON WEST PROPERTY LINE |