Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
Permit Number - T08EL01591
Inspection Description - ELECTRIC - FINAL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/11/2008 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
| 09/09/2008 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ALL ADDITIONS LEGAL 2) REMOVE CARPORT ON PROPERTY LINE AND REAR STORAGE OR PERMIT 3) POST HOUSE NUMBERS |
|
| 09/02/2008 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) COMPLY WITH PREVIOUS 7 & 1 2) CARPORT ON EAST PROPERTY LINE. PROVIDE PROOF ADDITION BEDROOM, BATH AND CLOSET INSPECTION APPROVALS |
|
| 08/21/2008 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) POST HOUSE NUMBERS 2) MISSING LIGHT FIXTURES EXTERIOR 3) MISSING DEAD FRONT SUB-PANEL EXTERIOR 220 4) EXTEND PRESSURE RELIEF LINE 6'-24" FROM GROUND WATER HEATER 5) PROVIDE 1" CLEARANCE WATER HEATER B-VENT FROM COMBUSTIBLES 6) EXPOSED ROMEX REAR PORCH PROVIDE PHYSICAL PROTECTION 7) PROVIDE PROOF PERMIT REAR ADDITION WITH ELECTRICAL AND PORCH ADDITION AT PROPERTY LINE AND CARPORT ENCLOSURE 7) PROVIDE WORKING SMOKE DETECTORS HALLWAY AND BEDROOMS 8) GFCI PROTECT BATH OUTLET 9) 2 WIRE CIRCUIT WITH GROUND OUTLETS MUST BE PROTECTED |