Permit: T08EL01546

Parcel: 110080660


Addresses:

2618 N COLUMBUS BL


Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Permit Number - T08EL01546

Inspection Description - ELECTRIC - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
01/30/2009 ELECTRIC - FINAL Approved IVRS - Inspection :*
01/29/2009 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. SEPARATE DOUBLE TAPPED CIRCUIT WIRES IN ELEC. PANEL IN FURNACE CLOSET
2. DURING INSPECTION OF PANEL, IT WAS NOTED THAT THERE IS A FLEX GAS LINE RUNNING THROUGH THE JACKET OF THE FURNACE. HARD GAS PIPE MUST PENETRATE THE JACKET.
3. HAVE LICENSED CONTRACTORS CORRECT THE ABOVE DEFICIENCIES AND THEN RECALL THE ELEC. FINAL