Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - RECONNECT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/14/2008 | ELECTRIC - RECONNECT | Approved | IVRS - Inspection :* | |
| 09/24/2008 | ELECTRIC - RECONNECT | Partial Approval | IVRS - Inspection :* 1) 30 DAY TEMP POWER FOR CONSTRUCTION ONLY 2) NOT TO BE LIVED IN-RECALL TO VERIFY PROGRESS |
|
| 09/08/2008 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) CLEAN ALL COMBUSTIBLES (WEEDS) FROM INSIDE OF WATER HEATER AND ENCLOSURE 2) GAS SUPPLY WILL NEED A SEDIMENT TRAP AT END OF PIPING BEFORE VALVE AT WATER HEATER AND GAS PACK UNIT 3) WILL NEED TO SEAL HOLE IN BLK WALL AT WEST END OF HOUSE 4) WILL NEED A EXT. LIGHT AT EXT. DOOR BACK OF HOUSE 5) SUBMIT AS BUILT DRAWINGS FOR PORCH OR MODIFY TO BRING UP TO CODE (ON SUPPORTS AND 2 X BEAM) 6) EXPOSE WATER HEATER TO VERIFY TPR LINE 3/4" 7) NEED TO PLUG TEE ON COLD WATER SIDE AT WATER HEATER 8) NEED TO CLEAN REGISTER ABOVE STOVE FOR VENTILATION 9) NEED TO BOND GAS LINE |
|
| 08/08/2008 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999* |