Permit: T08EL01389

Parcel: 107130710


Addresses:

26 W KELSO ST

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
12/16/2010 BUILDING - FINAL Approved
12/14/2010 BUILDING - FINAL Not ready for Inspection IVRS - Inspection :*
1) NO ACCESS AND GATE LOCKED
11/10/2010 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) POST HOUSE NUMBER VISIBLE FROM STREET
2) REAR FLOOD LIGHTS LACK PROPER CONNECTION ROMEX TO BOX
3) SECURE EXTERIOR GAS LINES TO CODE
4) ANTI-TILT STOVE
5) MISSING SMOKE ALARM HALLWAY
6) REAR BEDROOM WINDOW SECURITY BARS MUST OPERATE FREELY WITHOUT USE OF SEPERATE TOOLS FOR EMERGENCY EGRESS
PROVIDE ALL PAPERWORK FROM PAST INSPECTIONS AND INSPECTION CARD
7) OMIT DBL KEYED DEADBOLT EXIT DOOR
8) PROVIDE ALL PAPERWORK FROM PAST INSPECTIONS AND INSPECTION CARD
9) PROVIDE PROOF INTERMEDIATE INSPECTIONS OR RECALL
10/26/2010 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) ITEMS 1,3 & 9 FROM PREVIOUS INSPECTION
2) DO TO NUMEROUS INSPECTIONS WITHOUT A PROPER CORRECTIONS A REFEE MUST BE PAID
08/18/2010 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) VENT OUTSIDE OF REAR DOOR TO EXTEND 12" PAST ROOF LINE-SEWER VENT NOT DRYER
2) ANTI-SIPHON DEVICES REQUIRED ON HOSE BIBBS
3) PROPERLY SECURE RISER AND ELECTRIC SERVICE-NOT PROPERLY SECURED-ROOF STRUTS AND PLYWOOD ARE INADEQUATE, AS WELL AS THE BRACKET ATTACHMENTS
4) PROPERLY LABEL DISCONNECTS
5) POST ADDRESS LABEL ON SERVICE PANEL
6) MISSING COVER PLATES IN REAR BEDROOM
7) NEED SMOKE DETECTOR IN REAR BEDROOM
8) REMOVE GAS LINE LEADING INTO YARD FROM WATER HEATER
9) GAS AND WATER BOND REQUIRED-SECURE BOND WIRES TO HOUSE

NEW COMMENTS DUE TO NEW EQUIPMENT:
1) CAP DRYER GAS LINE AT VALVE OR INSTALL DRYER
2) CAULK KITCHEN SINK AT COUNTER
3) INSTALL TPRV DISCHARGE LINE AT WATER HEATER
4) ALL BEDROOM WINDOWS MUST BE READILY OPERABLE FOR EMERGENCY ESCAPE WITHOUT THE USE OF SPECIAL TOOLS OR KNOWLEDGE