Permit: T08EL01306

Parcel: 120092230


Addresses:

138 E RODEO DR

Inspection Status: Approved

Inspection History: ELECTRIC - RECONNECT

Date Description Inspector Results Comments
07/18/2008 ELECTRIC - RECONNECT Approved IVRS - Inspection :*
07/15/2008 ELECTRIC - RECONNECT Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PROVIDE PHYSICAL PROTECTION EXTERIOR ROMEX
2) REPLACE PVC FOR PROTECTION
3) MISSING BLANK COVERS CIRCUIT 4 X 5 SUB PANEL
4) SECURE MAIN SERVICE PANEL OVER 36" IN HEIGHT PER CODE
5) INDENTIFY ALL CIRCUITS SUB PANEL
6) GFCI PROTECT KITCHEN COUNTER OUTLET
7) GLOBE BATH FIXTURE
8) GFCI PROTECT BATH OUTLET