Permit: T08EL01228

Parcel: 140171120


Addresses:

1326 E NEVADA DR

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
07/11/2008 ELECTRIC - FINAL Approved IVRS - Inspection :*
07/09/2008 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. NEED BUSHING ON CONDUIT COMING INTO SERVICE PANEL
2. NEED NO-LUX ON ALL ALUMINUM CIRCUITS IN SERVICE PANEL
3. NEED TO POST ADDRESS AT SERVICE PANEL
4. NEED GFI PROTECTED RECEPTACLE AT BATH
5. WILL CHECK RECEPTACLES AT KITCHEN WHEN POWER IS ENERGIZED
6. W/HEATER TP LINE NEEDS TO TERMINATE OUTSIDE OR INTO A RECEPTOR
7. NEED HI/LO COMBUSTION AIR AT LAUNDRY ROOM

ITEMS 5, 6 AND 7 CAN BE INSPECTED AT FINALS