Permit: T08EL01213

Parcel: 130142590


Addresses:

4054 E 25TH ST

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
09/10/2008 ELECTRIC - FINAL Approved IVRS - Inspection :*
09/08/2008 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
WATER HEATER TO BE PROPERLY GROUNDED
NEED TO CONNECT EQUIPMENT GROUNDING CONDUCTOR
TO WATER HEATER
08/11/2008 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
COMPLETE ALL PREVIOUS INSPECTION ITEMS.
HAVE ALL WALL PLATES INSTALLED
07/10/2008 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. ALL KITCHEN COUNTER RECEPTACLES TO BE GFI PROTECTED
2. CLOSE OPEN COVER WIRING COMPARTMENT WATER HEATER AND GROUND WATER HEATER
3. INSTALL SMOKE DETECTORS IN BEDROOMS PER INSTRUCTIONS
4. CHECK ALL SMOKE DETECTORS OPERATING. AC ONLY DETECTOR TO BE REPLACED TO HAVE BATTERY BACK UP ALSO
5. CLOSET LIGHT MASTER CLOSET TO BE 100% ENCLOSED
07/08/2008 ELECTRIC - FINAL Denied IVRS - Inspection :
There is no access to the site.| 920*
UNIT LOCKED. NO ACCESS.