Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/23/2008 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
| 07/17/2008 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SAME AS BEFORE; SPOKE WITH RICHARD ELECTRICIAN AND WILL COMPLY |
|
| 07/16/2008 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NO ONE HOME 2) NEED ENTRANCE TO INSIDE 3) WAS OLD GRD. WIRE REMOVED ? 4) WHAT IS #4 CU. ATTACHED TO ? |
|
| 07/11/2008 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. VERIFY AL. WIRE FROM METER IS #2 2. INSTALL NEW WIRE FROM J.BOX TO SERV. WIRE HAS BEEN HEAT DAMAGED 3. MAIN BREAKER IS TO BE OF SAME MANUFACTURER AS (PANEL SERV) 4. INSTALL NEW BREAKER FOR SUB-PANEL 5. BACK FED MAIN REQUIRES A LOCK DOWN KIT TO PREVENT REMOVAL 6. REMOVE SUB-PANEL COVER CHECK INSIDE 7. ALL FUSES ARE 30 AMP., SIZE FUSES PER WIRE 8. WRAP ALL WIRE IN TAPE OLD WIRE AT J-BOX |
|
| 07/02/2008 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SECURE CONNECTION TO J-BOX EXTERIOR AT PANEL 2) REPLACE DAMAGED BREAKERS MAIN SERVICE PANEL 3) PROVIDE PHYSICAL PROTECTION ROMEX IN LAUNDRY/ STORAGE ROOM 4) GFCI PROTECT KITCHEN OUTLETS 5) SMOKE DETECTORS BEDROOMS 6) PROVIDE GAS AND WATER BOND 7) PROVIDE PROOF OF LAUNDRY/STORAGE PERMIT 8) 2 WIRE SYSTEM WITH GAROUNDED OUTLETS |
|
| 06/30/2008 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NO ACCESS TO INTERIOR OF UNIT 8:15 AM-RECALL |