Permit: T08EL01197

Parcel: 12913210C


Addresses:

1201 E 33RD ST

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
07/23/2008 ELECTRIC - FINAL Approved IVRS - Inspection :*
07/17/2008 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SAME AS BEFORE; SPOKE WITH RICHARD ELECTRICIAN AND WILL COMPLY
07/16/2008 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NO ONE HOME
2) NEED ENTRANCE TO INSIDE
3) WAS OLD GRD. WIRE REMOVED ?
4) WHAT IS #4 CU. ATTACHED TO ?
07/11/2008 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. VERIFY AL. WIRE FROM METER IS #2
2. INSTALL NEW WIRE FROM J.BOX TO SERV. WIRE HAS BEEN HEAT DAMAGED
3. MAIN BREAKER IS TO BE OF SAME MANUFACTURER AS (PANEL SERV)
4. INSTALL NEW BREAKER FOR SUB-PANEL
5. BACK FED MAIN REQUIRES A LOCK DOWN KIT TO PREVENT REMOVAL
6. REMOVE SUB-PANEL COVER CHECK INSIDE
7. ALL FUSES ARE 30 AMP., SIZE FUSES PER WIRE
8. WRAP ALL WIRE IN TAPE OLD WIRE AT J-BOX
07/02/2008 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SECURE CONNECTION TO J-BOX EXTERIOR AT PANEL
2) REPLACE DAMAGED BREAKERS MAIN SERVICE PANEL
3) PROVIDE PHYSICAL PROTECTION ROMEX IN LAUNDRY/ STORAGE ROOM
4) GFCI PROTECT KITCHEN OUTLETS
5) SMOKE DETECTORS BEDROOMS
6) PROVIDE GAS AND WATER BOND
7) PROVIDE PROOF OF LAUNDRY/STORAGE PERMIT
8) 2 WIRE SYSTEM WITH GAROUNDED OUTLETS
06/30/2008 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NO ACCESS TO INTERIOR OF UNIT 8:15 AM-RECALL