Inspection History Details
Inspection Status: Denied
Inspection History: ELECTRIC - FINAL
Permit Number - T08EL01072
Inspection Description - ELECTRIC - FINAL
Inspection Status - Denied
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/18/2008 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SMOKE DETECTORS NOT MOUNTED IN LOCATIONS REQUIRED IN INSTRUCTIONS, ALSO TO BE MINIMUM 36" FROM HVAC VENTS. READ INSTALL INSTRUCTIONS |
|
06/13/2008 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. NEED ADDRESS POSTED ON BUILDING 2. SERVICE DISCONNECT TO BE IDENTIFIED "UNIT C" 3. SERVICE DISCONNECT MISSING PROPER HUB FOR METER NIPPLE 4. SERVICE DISCONNECT MISSING NEUTRAL BOND SCREW 5. NEED GFI PROTECTION FOR ALL KITCHEN COUNTER AND BATHROOM LIGHT RECEPTACLES 6. NEED NEW SMOKE DETECTORS EACH BEDROOM AND HALLWAY - INSTALL PER MANUFACTURES INSTRUCTIONS |