Permit: T08EL01020

Parcel: 13728031A


Addresses:

841 W VIRGINIA ST

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
12/12/2008 ELECTRIC - FINAL Approved IVRS - Inspection :*
09/02/2008 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) POST HOUSE NUMBERS
2) PROTECT ROMEX FROM PHYSICAL DAMAGE UNDER 7' STORAGE ROOM
3) RELOCATE SMOKIES MINIMUM 36" FROM REGISTER
4) PROVIDE WATER AND GAS BONDS
5) PROVIDE SECONDARY GROUND ROD
6) SWITCH BOX ROMEX STORAGE WITHIN 8' FROM BOX
06/09/2008 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NEED SMOKIES IN BEDROOMS AND HALLWAY
2) NEED GFI RECEPTACLES AT KITCHEN COUNTER AND BATHS
3) SERVICE PANEL NEED NO LOX ON ALL ALUMINUM WIRES
4) NEED ELECTRIC UFER
5) FACE COVER ON SERVICE PANEL MISSING SCREWS
6) CONDUCTORS ON BUS BAR CANNOT BE MORE THAN 2 WIRES